Co13xxl - management and control of emergency stops

« Back to list
From €137

Control of emergency stops

Safety management in a compact 22.5 mm format

Mono or two-channel with wiring. "Low consumption" Inputs

Removable terminals

 

Performance level with AWAX controller: PL = d

Safety category: 3 (two-channel)

Time before dangerous failure: MTTFd = 240 years

Cycle before dangerous failure: B10d=100,000 at 5A

Risk duration: 20 ms max.

Cable severing protection: yes (opening of safety lines)

Safety contacts/diagnostics: 2x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant + 1x NO static 400 mA

Indicators: 3 LEDs for diagnostics

Reset: configurable by dip-switch (SR=Automatic, N=manual)

Mounting: symmetrical DIN 35mm rail on DIN 50022

Mounting: IP 20 electrical box

Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum

Temperature: -20°C to +60°C

Options :

Quantity :

Price :