XORF-SA - Non-autonomous safety switch with RFID coding

Controls the position of security doors with RFID encoding for wheeled vehicles

RFID sensor with 16 million codes
Suitable for metallic environments
Programmable code through auto-learning (no software or PC)
Level of performance with AWAX controller: up to PL = e
Safety category: up to 4 (EN 954-1) with AWAX controller
Time to dangerous failure: MTTFd = 40 years
  • Max activation distance: up to 24 mm
  • Security contact/diagnostics: 2 x redundant NO 50mA/30V and
  • 1 x 50mA auxiliary PNP
  • Detection encoding: inviolable multicode
  • Indicator: LED indicates code recognition
  • Reset: automatic
  • Attachment: 4 tamper-proof M4 screws (in base option: BH4)
  • Mounting position: 2 (double wall brackets)
  • Material: PA6
  • Electrical Connection: 50cm PUR cable with M12 connector
  • Sealing: IP 68
  • Standing room temperature: -30 °C to +50 °C.
  • Storage temperature: -40 °C to +85 °C
  • Marking: pad printing + serial number for traceability
  • Certificate: E2 10R-04 14053 (UTAC)
  • ISO 7637-2 (Pulse 1, 2a, 2b, 3a, 3b, 4)
Starting from :
91,00 €

Available

See all options
Guarantee 3 ans
  Ref Designation Prix Quantity  
5-3206-5-xorf-sa.png XORF-SA/MKT XORF-SA/MKT 91,00 €
5-3206-5-xorf-sa.png XORF-SA/MKT 220 XORF-SA/MKT 220 108,00 €
5-2948-5-xorf3.png XORF-SA/MKT CB01 XORF-SA/MKT - With management card 95,00 €
5-3206-5-xorf-sa.png XORF-SA/3M XORF-SA/3M 71,00 €
5-3206-5-xorf-sa.png XORF-SA/6M XORF-SA/6M 77,00 €
5-3206-5-xorf-sa.png XORF-SA/12M XORF-SA/12M 83,00 €
Documents
Dimension XORF-SA
Dimension XORF-SA
Login to your customer account to access all documents related to this product
Related products
AWAX 26XXL - Safety Relays - Self Check Box
Sensor controller on Acotom process / mechanical switches / emergency stops Output contacts 8A/250V Anti-gluing control of the reset button Ultra-fast "DLC" short-circuit check : Short-circuit detection in 2 µs, self-resetting Safety management in a compact 22.5 mm format 12V version for embedded applications Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3

Need information or advice?