Safety Switch stand alone

A revolutionary safety switch :
- Benefits PA6 housing: weather resistance, chemical attack
- Very good heat resistance
- Very good resistance to cold
- Very good resistance to chemicals and hydrocarbons
- Protection IP 67/68
- LED indicator for translucent area for total protection
- Mounting brackets for double-legged for detection // or perpendicular to the ground
AMX - Safety Switch stand alone
Controls the position of hazardous machine doors/cases with integrated self-checking

Contactless coded sensor with electronic technology and relays
IP68 PA6 / IP69K INOX316L
Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1
Performance level and category with AWAX controller: Cat 4 up to PL=e
Integrated safety level: SIL 2 according to IEC 61508
AMXR-S - Safety Switch stand alone with RFID coding
Controls the position of safety doors/casings with RFID encoding

RFID sensor with 16 million codes
Category 3 total security management without an external controller
Programmable code through auto-learning (no software or PC)
Level of performance with AWAX controller: up to PL = e
Safety category without an external controller: 3 (EN 954-1)
Cycle after dangerous failure: B10d = 2000000 at 2 Amps
XR530 - Badge access control reader with RFID coding
Card access control with RFID encoding

RFID sensor with 16 million codes
Lock control and two alarm levels
Programmable code through auto-learning (no software or PC)
AMX5CK - Safety Switch with person management in hazardous area
Position control for doors / casings on hazardous machinery
Manages person entry in hazard zones using an electrical locking key

Contactless encoded electronic sensor with relay
Category 3 total safety management without an external controller
Electrical locking key with position contact
MASSIMOTTO X5 - Safety Switch for single or double-wing doors
Position control for doors / casings on hazardous machinery

Contactless encoded electronic sensor with relay
Category 3 total safety management without an external controller
Suitable for groove profiles and single or double doors
OPTO2S - Miniature safety Switch
Position control for doors / casings on hazardous machinery

Contactless encoded electronic sensor with relay
Category 3 total safety management without an external controller
12V version for embedded applications
SSR - Safety Switch stand alone - Cat.1
Position control for doors / casings on hazardous machinery

Contactless encoded electronic sensor with relay
Up to 8 zone differentiation codes
Safety contacts 2A / 250V
Level of performance without an external controller: PL = c
Level of performance with AWAX controller: up to PL = e
VILGIL RS - Category 4 autonomous contactless safety switch

More information about: Safety Switch stand alone

A revolutionary safety sensor:
1) Benefits of PA6 housing: weather resistance, chemical attack
- Very good heat resistance
- Very good resistance to cold
- Very good resistance to chemicals and hydrocarbons
- Protection IP 67/68
- LED indicator for translucent area for total protection
- Mounting brackets for double-legged for detection // or perpendicular to the ground
2) Benefits INOX316L housing and mirror finish:
- Special food
- Severe Environment
- No bacterial adherence
- Easy cleaning
- IP 69K
- LED indicator with protective cover
- Mounting brackets for double-legged for detection // or perpendicular to the ground
3) Technological advantages:
- Suitable for doors / sliding or rotating housings
- No mechanical contact between the transmitter (key) and receiver (sensor)
- Large lateral alignment tolerance, axial, broad functional play (for guided poorly doors)
- Protection against fraud inviolable encoding magnetic field
- Output Cable UL2464 or PUR cable 50cm sturdy molded M12 UL20549
- Switching to failure cycle: B10d = 2 000 000 2A (adapted to the contactor control)
- Standalone Product with Performance Level PL d / cat.3 without adding housing / additional PLC
- Number of sensor in series: up to 100
- Signalling: by led and independent auxiliary output (status of each door told a serialization)
- Safety output: 2 lines redundant dry contacts 2A / 48V
- Auxiliary output: 1 contact PNP 250mA (sending voltage door open)
Choose AMX is choosing a technology solution twice
less expensive. It is simple, quickly mounts, robust,
autonomous and polyvalent