Redundant temperature sensing
Protective mobile device opening authorization at low temperature
INOX 316L housing
Application on industrial oven doors or any area to be protected against excessive temperature
- Mechanical cycle before failure: B10 = 1,000,000,000
- Electrical cycle before failure: B10 = 100,000 at 400 mA
- Safety Type: Positive
- Operating mode: in contact with the wall to be detected
- Activation temperature: 60°C or 90°C depending on the model
- Disabling temperature: 50°C
- Accuracy: +/- 3°C
- Safety contacts: 2 x NF 400 mA/24VDC redundant below temperature threshold
- Reset: automatic
- Attachment: 2 M4 screws not included; anti-rotation lugs provided
- Mounting position: 1 (4 x paste on screw-caps provided)
- Material: 316L stainless steel mirror polished case,
- Electrical connection: 50cm Ultra-soft silicone cord with M12 connector.
- Water resistance: IP 69K
- Temperature: -40°C to +180°C
- Marking: laser engraving with mechanical punching of the serial number for permanent traceability
URL User manual
Access
Aucun document disponible pour ce produit
AWAX 26XXL - Safety Relays - Self Check Box